207
edits
Line 39: | Line 39: | ||
1. A pellet-induced enhanced confinement regime (or PiEC) has been identified in Neutral Beam Injection (NBI) heated discharges made in TJ-II after the injection of a single cryogenic fuel pellet into its plasma core [1]. In addition to the expected increase in core electron density, the plasma diamagnetic energy content, as determined using a diamagnetic loop, is seen to rise by up to 40%, with respect to reference discharges without pellet injection. Furthermore, the energy confinement time is significantly enhanced when compared to predictions obtained using the 2004 International Stellarator Scaling law, ISS04. Indeed, the operational regimes of other stellarator devices, such as LHD and W7-X, can be similarly extended to performance well beyond those obtainable with gas puffing alone. | 1. A pellet-induced enhanced confinement regime (or PiEC) has been identified in Neutral Beam Injection (NBI) heated discharges made in TJ-II after the injection of a single cryogenic fuel pellet into its plasma core [1]. In addition to the expected increase in core electron density, the plasma diamagnetic energy content, as determined using a diamagnetic loop, is seen to rise by up to 40%, with respect to reference discharges without pellet injection. Furthermore, the energy confinement time is significantly enhanced when compared to predictions obtained using the 2004 International Stellarator Scaling law, ISS04. Indeed, the operational regimes of other stellarator devices, such as LHD and W7-X, can be similarly extended to performance well beyond those obtainable with gas puffing alone. | ||
2. New studies, performed with multiple pellet injections, have extended the TJ-II operational regime well beyond limits previously achieved in this device using NBI heating and gas puff. In order to achieve best results, the plasma target electron density should to be in the range 1x10^ | 2. New studies, performed with multiple pellet injections, have extended the TJ-II operational regime well beyond limits previously achieved in this device using NBI heating and gas puff [2]. In order to achieve best results, it has been determined that the plasma target electron density should to be in the range 1x10^19 m^-3 to 2.5x10^19 m^-3 and time separations between pellets should be close to energy confinement times, around 10 ms. It is also found, using a Charge Exchange Recombination Spectroscopy diagnostic, that while the plasma electron temperature is almost unaffected by such pellet injections, the majority ion temperature irises significantly due to reduced ion radial heat fluxes during the PiEC phase. It is also found that enhanced performance is independent of whether co- or counter-NBI heating beam is employed. Finally, record stored diamagnetic energy content and plasma beta values are achieved when the largest available pellets are employed. The results indicate that pellet injections extend the operational regime well beyond limits previously achieved in TJ-II without pellets. | ||
3. | |||
== References == | == References == |
edits