The core coil pack consists of three coils: the circular core (CC), the helix 1 (HX1), and the helix 2 (HX2).

The TJ-II coil system is listed in the table below. All coils are directly cooled by water flowing trough longitudinal holes in the conductors. All coils have a reinforced structure to avoid mechanical deformations.[1]

Coil Number Size (m) Turns
Circular (CC) 1 R = 1.5 24
Helical (HX)[2] 1 R = 1.5
swing = 0.07
24
Toroidal (TF) 28 r = 0.425 8
Toroidal (TF) 4 r = 0.475 9
Vertical (VF) 2 R = 2.25 16
Compensation (OH) 2 R = 0.78 20
Compensation (OH) 2 R = 2.29 1
Radial (R) 2 R = 0.74 7
Radial (R) 2 R = 2.24 5

The main helical field is produced by the CC, HX, and TF coils. The vertical field coils (VF) allow positioning the magnetic axis. The ohmic coils (OH) can generate a loop voltage of 0.1 V, intended to cancel spurious toroidal currents. The radial coils (R) produce a trimming radial field of up to 100 G, intended to compensate stray fields.

TJ-II Coils. Red: central. Yellow: helical. Blue: toroidal. Green: vertical. Brown and green: radial.

See also

References

  1. M. Medrano, M. Blaumoser, J. Alonso, G. Barrera, M. Pastor, C. Rubio, F. Pedrazo, and O. Heusmann, Strength considerations on the magnetic field coils of the Spanish Stellarator TJ-II, Fusion Engineering, 15th IEEE/NPSS Symposium (1993)