TJ-II:Biasing probe

From FusionWiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.
Layout of the biasing probe, mounted on the reciprocating probe drive

At TJ-II, a 2-D carbon composite mushroom shaped electrode (12 mm high with a diameter of 25 mm) has been developed and installed on a fast reciprocating probe drive. Typically, the electrode is inserted to a position 2 cm inside the last closed flux surface (LCFS) and biased positively (200-300 V) with respect to one of the two TJ-II limiters located in the Scrape-Off Layer region (about 0.5 cm beyond the LCFS). Measured electrode currents are in the range of 30-50 A.

The impact of biasing on confinement properties has been studied to some depth. [1] [2]

In 2009, the power source (originally DC) has been upgraded to allow modulation with a frequency of up to a few kHz.

Location: sector A8 (φ = 174.4 °). Signal names in the TJ-II database: 'PolI', 'PolV'.

Photo of the reciprocating drive of the biasing probe (top right)

References

  1. C. Silva et al, Transport and fluctuations during electrode biasing on TJ-II, Czech. J. Phys. 55 (2005) 1589
  2. M.A. Pedrosa et al, Transport and fluctuations during electrode biasing experiments on the TJ-II stellarator, Proc. 12st Fusion Energy Conf. (2006) EX-P4/40